- Capacity
- 4Mbit
- Technology
- FLASH
- Interface
- Parallel
- Supply voltage
- 2.7V ~ 3.6V
- Package
- 32-TFSOP (0.724", 18.40mm Width)
- Operating temperature
- -40°C ~ 85°C (TC)
- Organization
- 512K x 8
- Catalog lifecycle
- Obsolete (catalog)
Procurement requirements
The catalog status is Obsolete (catalog). For AT29BV040A-25TI, confirm current lifecycle and exact order-code availability. For legacy sourcing, agree lot traceability, storage/packing checks and an inspection scope; this does not establish current factory production.
RFQ brief
Related ordering variants
AT29BV040A-25TC
Operating temperature: AT29BV040A-25TI = -40°C ~ 85°C (TC); AT29BV040A-25TC = 0°C ~ 70°C (TC). These are catalog differences between ordering variants, not a declaration of board-level interchangeability.
Product-specific questions
Which read speed, package and temperature does 25TI select?
AT29BV040A-25TI is the 250 ns option in a 32-lead 32T TSOP package for -40°C–85°C case temperature. Its 512K x 8 parallel array uses A0–A18 and eight data lines. Read access time is separate from the internal sector erase/program cycle; a 250 ns suffix does not describe a write cycle or serial clock.
Atmel AT29BV040A — Rev.0383G–FLASH–5/03; architecture and pin configuration · 1, 2
Atmel AT29BV040A — Rev.0383G–FLASH–5/03; Ordering Information and Package Type · 12
Does tolerance of 5.5 V on address inputs permit a 5 V supply or data bus?
No. The documented operating supply is 2.7–3.6 V. The Input Levels section allows address/control inputs up to 5.5 V, but limits driven I/O lines to VCC + 0.6 V. These are separate pin conditions, not general 5 V tolerance for the entire device. Check both the host-to-memory data levels and the memory output-high specification when designing the interface.
Atmel AT29BV040A — Rev.0383G–FLASH–5/03; architecture and pin configuration · 1, 2
Atmel AT29BV040A — Rev.0383G–FLASH–5/03; Input Levels and DATA Polling · 3
Can the three-command software-protection prefix be omitted for a normal write?
No. This low-voltage family is programmed only through its software-protected programming procedure. The three-command prefix must begin every program operation, followed by the complete 256-byte sector load. An attempted write without the prefix does not program data, but can still start the internal timer so reads behave as polling during tWC. Do not copy the optional-SDP procedure of a different 5 V AT29C part.
Atmel AT29BV040A — Rev.0383G–FLASH–5/03; Software Data Protection Programming and byte loading · 2, 3
Why is a complete 256-byte image necessary for a one-byte change?
The device erases and reprograms a whole sector automatically. Load all intended bytes, keeping the sector address fixed; successive WE/CE loads must satisfy the 150 µs interval before the timer starts the internal cycle. The cited programming section says unloaded byte contents are indeterminate; leaving them out does not preserve old contents.
Atmel AT29BV040A — Rev.0383G–FLASH–5/03; Software Data Protection Programming and byte loading · 2, 3
What do I/O7 polling and I/O6 toggling actually report?
Read the last loaded byte for DATA polling: I/O7 is the complement of its loaded value during programming, then valid data returns on all outputs. Alternatively, consecutive reads show I/O6 toggling until the cycle completes. These reads are completion/status checks during tWC, not ordinary access to an already updated array.
Atmel AT29BV040A — Rev.0383G–FLASH–5/03; Input Levels and DATA Polling · 3
What changes after either 16K-byte boot block is locked?
The first and last 16K bytes have independent lockout. Once activated, the affected boot block cannot be erased or programmed and chip erase is disabled if either lock is set. Other sectors remain programmable by the normal procedure. A lot required for a new firmware image must therefore be checked for the relevant lockout state, not only for a readable device ID.
Atmel AT29BV040A — Rev.0383G–FLASH–5/03; Boot Block Programming Lockout · 4
Which programmed-state requirements belong in an RFQ for AT29BV040A-25TI?
Include the exactAT29BV040A-25TI order, 32T TSOP, 250 ns, -40°C–85°C, quantity, destination and required date. Specify blank or approved programmed material, binary/checksum, complete 256-byte sector handling and boot-lock verification when applicable. Agree date/lot markings, carrier packaging and inspection documents. Availability, MOQ, price and delivery commitments stay in the original quotation system.
Atmel AT29BV040A — Rev.0383G–FLASH–5/03; Software Data Protection Programming and byte loading · 2, 3
Atmel AT29BV040A — Rev.0383G–FLASH–5/03; Boot Block Programming Lockout · 4
Atmel AT29BV040A — Rev.0383G–FLASH–5/03; Ordering Information and Package Type · 12