Selection and controller requirements
AT29C512-70JC is a 64K x 8 parallel Flash order with 70 ns read access, 32J, 32-lead PLCC, 0°C–70°C and 5 V ±10% operation. Reprogramming uses complete 128-byte sectors.
Procurement requirements
The catalog status is Obsolete (catalog). For AT29C512-70JC, confirm current lifecycle and exact order-code availability. For legacy sourcing, agree lot traceability, storage/packing checks and an inspection scope; this does not establish current factory production.
The archived Rev.0456F–FLASH–12/02 ordering page labels this family “Not recommended for New Designs”. This is dated document guidance, not an independently checked current manufacturer lifecycle notice.
RFQ brief
Related ordering variants
AT29C512-70PC
Package: AT29C512-70JC = 32-LCC (J-Lead); AT29C512-70PC = 32-DIP (0.600", 15.24mm). These are catalog differences between ordering variants, not a declaration of board-level interchangeability.
Product-specific questions
What does 70JC select in the AT29C512 ordering table?
AT29C512-70JC selects 70 ns address access, 32J, 32-lead PLCC and the 0°C–70°C operating range. The device uses a 5 V ±10% supply and a 64K x 8 parallel array with A0–A15 and I/O0–I/O7. The speed suffix describes a read timing limit, not a serial clock rate or the internal erase/program time.
Atmel AT29C512 — Rev.0456F–FLASH–12/02; architecture and package pinout · 1
Atmel AT29C512 — Rev.0456F–FLASH–12/02; Ordering Information and Package Type · 14
Can one changed byte be written without preserving the other 127 bytes?
No. Reprogramming combines sector erase and programming of 128 bytes. The cited revision states that an unloaded byte has indeterminate contents. Build the complete intended sector image, including data that must remain unchanged. A0–A6 select the byte and A7–A15 select the sector. Successive WE/CE byte-load transitions must meet the 150 µs interval; expiry ends loading and starts the internal cycle.
Atmel AT29C512 — Rev.0456F–FLASH–12/02; Device Operation: sector load/program · 2, 3
Does cycling power clear software data protection?
No. The cited revision allows SDP to be enabled or disabled by its command sequences and states that Atmel ships the device with SDP disabled. Once enabled, each programming cycle requires the three-command prefix; power transitions do not reset that state. This is a programming-protection state, not a statement about whether a purchased legacy lot is blank or how it was previously configured.
Atmel AT29C512 — Rev.0456F–FLASH–12/02; Device Operation: sector load/program · 2, 3
Which address and bits indicate completion of the internal program cycle?
DATA polling reads the last byte loaded: during programming, I/O7 returns the complement of its loaded value; after completion, all outputs show valid data. The alternative toggle check observes I/O6 changing between successive reads until completion. A read during tWC is a status/polling operation, so it must not be interpreted as ordinary array data.
Atmel AT29C512 — Rev.0456F–FLASH–12/02; DATA Polling and Toggle Bit · 4
Does 64K x 8 mean 512 kilobytes?
No. AT29C512 contains 65,536 eight-bit locations, totaling 512 Kbit or 64 KiB. A0–A15 address the byte locations; the sector load uses A0–A6 as the 128-byte offset. A larger 128K x 8 device needs another address bit and a corresponding memory-map review; matching a 32-pin package does not establish a drop-in replacement.
Atmel AT29C512 — Rev.0456F–FLASH–12/02; architecture and package pinout · 1
What should an RFQ for AT29C512-70JC say about the programmed state?
Specify AT29C512-70JC, 70 ns, 32J, 32-lead PLCC, 0°C–70°C, quantity, destination and required date. State blank or programmed material and, if programmed, the approved binary/checksum and verification scope. Include the SDP state and the complete 64 KiB image requirement. Agree date/lot identification, carrier packaging and inspection records. Current availability, MOQ and pricing remain in the original quotation system.
Atmel AT29C512 — Rev.0456F–FLASH–12/02; Device Operation: sector load/program · 2, 3
Atmel AT29C512 — Rev.0456F–FLASH–12/02; Ordering Information and Package Type · 14